Label
Joins every physical terminal wired to a label with the same tag, on this sheet and inside the subsystems on it, as one node, without a wire.
- electrical
- Gradara equations
- 1 port
connectionLabelLibraryRoutingDescription
Joins physical terminals by tag: every terminal wired to a label with the same tag is one node, as if they were wired together. Use it for a supply rail, a ground return, or a shaft that many parts share. The label takes the domain of the first terminal you connect (electrical, rotational, translational, thermal, magnetic, or 3-phase).
Labels reach down a hierarchy, never up: a label inside a subsystem joins the labels with its tag on its sheet and on the sheets above it, so a rail labelled at the top reaches every subsystem that labels it. Two subsystems side by side are joined only through a label above them.
Example
Goto, From, and connection labels A signal and a supply rail carried across the sheet by tag, without wires.
Also in this example:Sine waveGainGroundResistorDC voltageVoltage sensorGotoFrom
Ports
Conserving terminals 1
-
p
A physical terminal of the label’s domain. Like a wire, the label adds no equations of its own.
Equations
all terminals on labels [tag]: one node (equal potentials, flows summing to zero)
Assumptions and limitations
- Labels with one tag must share one domain.
- A tag is a letter, then letters, digits, or _ (up to 32).
Tips
- Flip a label (⌘/Ctrl + I) to put its terminal on the other side.
- Its properties list the other labels it joins, here and above, with Show to jump to each. Select it to highlight the labels with its tag on the sheet.
- Hover a label and click the faded label past it to add another with the same tag.
See also
Select a block in Gradara and press F1 to open its page offline.