Label

Joins every physical terminal wired to a label with the same tag, on this sheet and inside the subsystems on it, as one node, without a wire.

  • electrical
  • Gradara equations
  • 1 port
BlockLabelKindconnectionLabelLibraryRouting

Description

Joins physical terminals by tag: every terminal wired to a label with the same tag is one node, as if they were wired together. Use it for a supply rail, a ground return, or a shaft that many parts share. The label takes the domain of the first terminal you connect (electrical, rotational, translational, thermal, magnetic, or 3-phase).

Labels reach down a hierarchy, never up: a label inside a subsystem joins the labels with its tag on its sheet and on the sheets above it, so a rail labelled at the top reaches every subsystem that labels it. Two subsystems side by side are joined only through a label above them.

Example

Goto, From, and connection labels A signal and a supply rail carried across the sheet by tag, without wires.

SineGain 2Gain −1DC 10 VGroundLoad 10 ΩGround (load)Rail voltage
In Gradara, select a Label block and press F1, then choose Open example. It opens as a new model in My models, ready to run.

Also in this example:Sine waveGainGroundResistorDC voltageVoltage sensorGotoFrom

Ports

Conserving terminals 1

  • p

    A physical terminal of the label’s domain. Like a wire, the label adds no equations of its own.

Equations

Modelica
all terminals on labels [tag]: one node (equal potentials, flows summing to zero)

Assumptions and limitations

  • Labels with one tag must share one domain.
  • A tag is a letter, then letters, digits, or _ (up to 32).

Tips

  • Flip a label (⌘/Ctrl + I) to put its terminal on the other side.
  • Its properties list the other labels it joins, here and above, with Show to jump to each. Select it to highlight the labels with its tag on the sheet.
  • Hover a label and click the faded label past it to add another with the same tag.

See also

Select a block in Gradara and press F1 to open its page offline.