Inverse Clarke transform
Stationary-frame (α, β) pair back to three phases, with the zero-sequence input added to each.
- signal
- Modelica Standard Library
- 6 ports
inverseClarkeLibraryControlDescription
Converts a stationary-frame (α, β) pair back into three phase quantities, adding the zero-sequence input to each phase (the Modelica library space-phasor transform in reverse). It undoes Clarke transform exactly.
In a field-oriented drive it turns the α, β voltage commands into the three phase voltages for the inverter.
Example
Clarke and Park transforms Balanced three-phase signals become a rotating α, β pair, then constant d and q, and go back out through a controlled three-phase source.
Also in this example:ConstantSine waveClockGainClarke transformPark transformGroundControlled 3-phase voltage3-phase resistorStar point3-phase current sensor
Ports
Inputs 3
-
α
alphaα axis, aligned with phase a.
-
β
betaβ axis, 90° ahead of α.
-
0
zeroZero-sequence (common-mode) component added to every phase. Wire a Constant 0 when there is none.
Outputs 3
-
a
vaPhase a.
-
b
vbPhase b.
-
c
vcPhase c.
Equations
va = alpha + zero vb = −alpha/2 + (√3/2) · beta + zero vc = −alpha/2 − (√3/2) · beta + zero
Implementation
Modelica.Electrical.Machines.SpacePhasors.Blocks.FromSpacePhasorTips
- The zero input must be connected; it is how common-mode injection (third-harmonic or min–max) enters a modulator.