Inverse Clarke transform

Stationary-frame (α, β) pair back to three phases, with the zero-sequence input added to each.

  • signal
  • Modelica Standard Library
  • 6 ports
BlockInverse Clarke transformKindinverseClarkeLibraryControl

Description

Converts a stationary-frame (α, β) pair back into three phase quantities, adding the zero-sequence input to each phase (the Modelica library space-phasor transform in reverse). It undoes Clarke transform exactly.

In a field-oriented drive it turns the α, β voltage commands into the three phase voltages for the inverter.

Example

Clarke and Park transforms Balanced three-phase signals become a rotating α, β pair, then constant d and q, and go back out through a controlled three-phase source.

iaibicClarkeParkTimeθ = 2π·50·tZero sequence 0Inverse ClarkeControlled 3-phase sourcePhase currentsLoad 10 ΩStar pointGroundSource neutral
In Gradara, select a Inverse Clarke transform block and press F1, then choose Open example. It opens as a new model in My models, ready to run.

Also in this example:ConstantSine waveClockGainClarke transformPark transformGroundControlled 3-phase voltage3-phase resistorStar point3-phase current sensor

Ports

Inputs 3

  • αalpha

    α axis, aligned with phase a.

  • βbeta

    β axis, 90° ahead of α.

  • 0zero

    Zero-sequence (common-mode) component added to every phase. Wire a Constant 0 when there is none.

Outputs 3

  • ava

    Phase a.

  • bvb

    Phase b.

  • cvc

    Phase c.

Equations

Modelica
va = alpha + zero
vb = −alpha/2 + (√3/2) · beta + zero
vc = −alpha/2 − (√3/2) · beta + zero

Implementation

Modelica Standard Library 4.1.0Modelica.Electrical.Machines.SpacePhasors.Blocks.FromSpacePhasor
MSL documentation

Tips

  • The zero input must be connected; it is how common-mode injection (third-harmonic or min–max) enters a modulator.

Used in

These larger examples use it too. Open them from Examples in the app.

  • PMSM · Field-oriented control

See also

Select a block in Gradara and press F1 to open its page offline.