Dead zone
Zero output inside ±half-width.
- signal
- Gradara equations
- 2 ports
- 1 parameter
deadzoneLibraryNonlinearDescription
Outputs zero while the input is within ±Half-width. Outside that band the output is the input shifted toward zero by Half-width, so it is continuous at the band edges.
Example
Nonlinearities Saturation, dead zone, relay, and rate limiter acting on the same sine.
Sine, amplitude 2Saturation ±1Dead zone ±0.5RelayRate limit 2/s
Also in this example:SaturationSine waveRelayRate limiter
Ports
Inputs 1
-
u
Input signal.
Outputs 1
-
y
Output signal.
Parameters
-
Half-width
start0.1≥ 0
Half-width of the dead band. 0 or more; 0 passes the input unchanged.
Equations
Modelica
y = u − start if u > start y = u + start if u < −start y = 0 otherwise
Implementation
The block’s Modelica model
y = if u > start then u - start else (if u < -start then u + start else 0);
Assumptions and limitations
- The band is symmetric around zero.
See also
Select a block in Gradara and press F1 to open its page offline.