Dead zone

Zero output inside ±half-width.

  • signal
  • Modelica Standard Library
  • 2 ports
  • 1 parameter
BlockDead zoneKinddeadzoneLibraryNonlinear

Description

Outputs zero while the input is within ±Half-width (the Modelica library dead zone). Outside that band the output is the input shifted toward zero by Half-width, so it is continuous at the band edges.

Example

Nonlinearities Saturation, dead zone, relay, and rate limiter acting on the same sine.

Sine, amplitude 2Saturation ±1Dead zone ±0.5RelayRate limit 2/s
In Gradara, select a Dead zone block and press F1, then choose Open example. It opens as a new model in My models, ready to run.

Also in this example:RelaySine waveSaturationRate limiter

Ports

Inputs 1

  • u

    Input signal.

Outputs 1

  • y

    Output signal.

Parameters

  • Half-widthstart0.1

    ≥ 0

    Half-width of the dead band. 0 or more; 0 passes the input unchanged.

Equations

Modelica
y = u − start if u > start
y = u + start if u < −start
y = 0 otherwise

Implementation

Modelica Standard Library 4.1.0Modelica.Blocks.Nonlinear.DeadZone
MSL documentation

Assumptions and limitations

  • The band is symmetric around zero.

See also