3-phase inductor
Inductor in each phase.
- 3-phase
- Modelica Standard Library
- 2 ports
- 1 parameter
threePhaseInductorLibrary3-phaseDescription
Three independent linear inductors, one in each phase between plug_p and plug_n, with no coupling between phases.
Example
Three-phase loads A 10 V three-phase supply into a resistive star load, a series R–L star load, and a capacitor bank in delta.
10 V 50 HzStar supplyGround supplyStar (R)Ground (R)Star (R–L)Ground (R–L)PowerCurrents (R)R 10 ΩR 10 Ω (R–L)Currents (R–L)L 31.8 mHCurrents (C)C 100 µFDeltaPhase aPhase bPhase cv av bv cGround aGround bGround c
Also in this example:Voltage sensorGround3-phase AC source3-phase resistor3-phase capacitorStar pointDelta connectionPhase a tapPhase b tapPhase c tap3-phase current sensor3-phase power sensor
Ports
Conserving terminals 2
-
+
plug_pThree-phase plug (phases a, b, c). Current into plug_p is counted as positive.
-
−
plug_nThree-phase plug (phases a, b, c).
Parameters
-
Inductance per phase
L0.01 H≥ 0
Inductance of each phase, in henries. Positive.
Equations
Modelica
vk = L · d(ik)/dt for k = a, b, c
Implementation
Modelica Standard Library 4.1.0
MSL documentation Modelica.Electrical.Polyphase.Basic.InductorAssumptions and limitations
- No mutual coupling, saturation, or winding resistance.
Tips
- Use it as a line reactor or grid impedance, often in series with a 3-phase resistor.
See also
Select a block in Gradara and press F1 to open its page offline.