Flux sensor
Magnetic flux through the sensor.
- signal
- magnetic
- Modelica Standard Library
- 3 ports
fluxSensorLibraryMagneticDescription
Measures the magnetic flux through it. Insert it in series in the flux path; it has no magnetic potential drop.
Example
Magnetic circuits A 100-turn winding drives flux through an air gap and a core, next to magnetic sources and a variable reluctance.
1 VGroundR 1 ΩWinding 100 turnsCore fluxAir gapCoreMagnetic groundGap mmfmmf 100 AGround (mmf)R_m signalVariable reluctanceFlux (variable)Ground (variable)50 ASignal mmfGround (signal)Permeance 1 µWb/AFlux (permeance)Ground (permeance)Flux 1 mWbGround (flux)Reluctance 10⁶mmf acrossGround (reluctance)
Also in this example:DC voltageStepGroundSine waveResistorReluctancePermeanceVariable reluctanceWindingMagnetic groundMMF sourceControlled MMF sourceFlux sourceMMF sensor
Ports
Outputs 1
-
Phi
Flux from port_p to port_n through the sensor, in webers.
Conserving terminals 2
-
+
port_pPositive magnetic port.
-
−
port_nNegative magnetic port.
Equations
Modelica
Phi = port_p.Φ port_p.V_m = port_n.V_m
Implementation
Modelica Standard Library 4.1.0
MSL documentation Modelica.Magnetic.FluxTubes.Sensors.MagneticFluxSensorSee also
Select a block in Gradara and press F1 to open its page offline.