Temperature difference sensor
Temperature difference between ports a and b.
- signal
- thermal
- Modelica Standard Library
- 3 ports
relTemperatureSensorLibraryThermalDescription
Measures the temperature difference between two heat ports. It draws no heat from either.
Example
Cooling a hot part A 10 W part cools through a thermal resistance into a heatsink that convects and radiates to 20 °C.
10 WPart 100 J/KHeat flowR 2 K/WHeatsink 500 J/Kh·A 5 W/KConvectionAir 20 °CRadiationRoom 20 °CPart temperatureAcross R350 KHeld at 350 KG 1 W/KBody 100 J/K20 W at 1500 sHeaterBody temperature
Also in this example:ConstantStepHeat capacitorThermal conductorThermal resistorConvectionRadiationFixed temperatureTemperature sourceFixed heat flowHeat flow sourceTemperature sensorHeat flow sensor
Ports
Outputs 1
-
ΔT
T_relTemperature difference port_a.T − port_b.T, in kelvin.
Conserving terminals 2
-
a
port_aHeat port a. No heat flows through it.
-
b
port_bHeat port b. No heat flows through it.
Equations
Modelica
T_rel = port_a.T − port_b.T port_a.Q_flow = 0, port_b.Q_flow = 0
Implementation
Modelica Standard Library 4.1.0
MSL documentation Modelica.Thermal.HeatTransfer.Sensors.RelTemperatureSensorSee also
Select a block in Gradara and press F1 to open its page offline.