Fixed temperature
Holds its port at a constant temperature.
- thermal
- Modelica Standard Library
- 1 port
- 1 parameter
fixedTemperatureLibraryThermalDescription
Holds its port at a constant temperature, supplying or absorbing whatever heat flow that takes. Use it for ambient air, a coolant, or a heat sink held at a known temperature.
Example
Cooling a hot part A 10 W part cools through a thermal resistance into a heatsink that convects and radiates to 20 °C.
10 WPart 100 J/KHeat flowR 2 K/WHeatsink 500 J/Kh·A 5 W/KConvectionAir 20 °CRadiationRoom 20 °CPart temperatureAcross R350 KHeld at 350 KG 1 W/KBody 100 J/K20 W at 1500 sHeaterBody temperature
Also in this example:ConstantStepHeat capacitorThermal conductorThermal resistorConvectionRadiationTemperature sourceFixed heat flowHeat flow sourceTemperature sensorHeat flow sensorTemperature difference sensor
Ports
Conserving terminals 1
-
T
portHeat port held at T.
Parameters
-
Temperature
T293.15 K≥ 0
Temperature, in kelvin (293.15 K is 20 °C). Must be ≥ 0.
Equations
Modelica
port.T = T
Implementation
Modelica Standard Library 4.1.0
MSL documentation Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureSee also