3-phase capacitor
Capacitor in each phase.
- 3-phase
- Modelica Standard Library
- 2 ports
- 1 parameter
threePhaseCapacitorLibrary3-phaseDescription
Three independent linear capacitors, one in each phase between plug_p and plug_n.
Example
Three-phase loads A 10 V three-phase supply into a resistive star load, a series R–L star load, and a capacitor bank in delta.
10 V 50 HzStar supplyGround supplyStar (R)Ground (R)Star (R–L)Ground (R–L)PowerCurrents (R)R 10 ΩR 10 Ω (R–L)Currents (R–L)L 31.8 mHCurrents (C)C 100 µFDeltaPhase aPhase bPhase cv av bv cGround aGround bGround c
Also in this example:Voltage sensorGround3-phase AC source3-phase resistor3-phase inductorStar pointDelta connectionPhase a tapPhase b tapPhase c tap3-phase current sensor3-phase power sensor
Ports
Conserving terminals 2
-
+
plug_pThree-phase plug (phases a, b, c). Current into plug_p is counted as positive.
-
−
plug_nThree-phase plug (phases a, b, c).
Parameters
-
Capacitance per phase
C0.00001 F≥ 0
Capacitance of each phase, in farads. Positive.
Equations
Modelica
ik = C · d(vk)/dt for k = a, b, c
Implementation
Modelica Standard Library 4.1.0
MSL documentation Modelica.Electrical.Polyphase.Basic.CapacitorAssumptions and limitations
- No leakage or series resistance.
See also
Select a block in Gradara and press F1 to open its page offline.